Document Citation: 19 CCR 3.05

Header:
CALIFORNIA CODE OF REGULATIONS
TITLE 19. PUBLIC SAFETY
DIVISION 1. STATE FIRE MARSHAL
CHAPTER 1. GENERAL FIRE AND PANIC SAFETY STANDARDS
SUBCHAPTER 1. ADMINISTRATION
ARTICLE 3. GENERAL PROVISIONS


Date:
08/31/2009

Document:
19 CCR 3.05 (2011)

ยง 3.05. Fire Department Access and Egress

(a) Roads. Required access roads from every building to a public street shall be all-weather hard-surfaced (suitable for use by fire apparatus) right-of-way not less than 20 feet in width. Such right-of-way shall be unobstructed and maintained only as access to the public street.

EXCEPTION: The enforcing agency may waive or modify this requirement if in his opinion such all-weather hard-surfaced condition is not necessary in the interest of public safety and welfare.

(b) Roofs. No person shall install or maintain any security barrier such as barbed wire fencing, razor wire fencing, chain link fencing, or any other fencing material, cable, aerial, antenna, or other obstruction on the roof of any commercial establishment in such a manner as to obstruct or render egress or access hazardous in the event of fire or other emergency.

EXCEPTION: Guy wire, rods and aerial antenna masts may be attached to a roof structure having a slope of less than 30 degrees provided there is full clearance of seven feet or more between the roof and said obstruction. Guy wire or rods required to support aerial or antenna masts may be attached to a roof structure a lateral distance from the mast not in excess of one-sixth the height of the mast.